Effect of impeller diameter to vessel diameter ratio on gas holdup

Mohd. Sobri Takriff, and W.R. Penney, and J.B. Fasano, (2000) Effect of impeller diameter to vessel diameter ratio on gas holdup. Jurnal Kejuruteraan, 12 .

Full text not available from this repository.

Official URL: http://www.ukm.my/jkukm/index.php/jkukm

Abstract

Numerous gas holdup correlations have been developed for predicting gas holdup in agitated vessels. However; gas holdup studies were only limited to the use of impeller diameter to vessel diameter ratio (Di/DT) of approximately 1/3. None of the available correlations considered the effect of (Di/DT) variation on gas holdup. This work was carried out to investigate this effect. The results of this investigation showed that the gas holdup increases with (Di/DT) ratio. The effect of (Di/DT) variation on gas holdup was correlated, with e = 2.0(NaNFr)O.6NRe 0.1 (Di/DT)2.5 , for an air-water mixture. The (Di/DT) used in this work ranged from 0.36 to 0.53

Item Type:Article
Journal:Jurnal Kejuruteraan
ID Code:1366
Deposited By: Ms. Nor Ilya Othman
Deposited On:18 May 2011 04:34
Last Modified:11 Oct 2011 03:45

Repository Staff Only: item control page