Performance study of air-based photovoltaic-thermal (PV/T) collector with different designs of heat exchanger

Mohd. Yusof Hj. Othman, and Faridah Hussain, and Kamaruzzman Sopian, and Baharuddin Yatim, and Hafidz Ruslan, (2013) Performance study of air-based photovoltaic-thermal (PV/T) collector with different designs of heat exchanger. Sains Malaysiana, 42 (9). pp. 1319-1325. ISSN 0126-6039

[img]
Preview
PDF
1MB

Official URL: http://www.ukm.my/jsm/

Abstract

Three different designs of heat exchanger, V-groove, honeycomb and stainless steel wool had been tested to study their effectiveness in improving the overall performance of a photovoltaic/thermal (PV/T) air base solar collector. Heat exchangers were installed horizontally into the channel located at the back side of the PV module. The system was tested at irradiance of 828 W/m2 with mass flow rate spanning from 0.02 kg/s to 0.13 kg/s. It was observed that at mass flow rate of 0.11 kg/s, the maximum thermal efficiency of the system with V-groove is 71%, stainless steel wool is 86% and honeycomb is 87%. The electrical efficiency of the systems is 7.04%, 6.88% and 7.13%, respectively. The experimental results showed that honeycomb design is the most efficient design as heat exchanger. The design which is simple and compact is suitable for building integration.